Your browser is not supported. For the best experience, a newer version or another browser is recommended.

SIFIN Antisera

Number of articles 33
Sort
Item no.
Display per page
Page 1 of 2
TR1111

Anti-Salmonella I (A-E) records all Salmonella serovars of the groups A-E and the Vi-antigen in slide agglutination.

TR1111-01

Anti-Salmonella I (A-E) records all Salmonella serovars of the groups A-E and the Vi-antigen in slide agglutination.

Anti-Shigella I
TR1811

The test reagents are intended for use in the serological detection and the determination of the serovar of Shigella strains isolated from test material of human or other origin using the slide agglutination test.

Principle of the test: If the Shigella strain possesses an antigen covered by the test reagent, this antigen becomes bound when mixed with the specific antibody. The antigen-antibody reaction results in clearly visible agglutination of the strain.

TR1811-01

Anti-Shigella IGroup B + D

Anti-Shigella sonnei S- and F-form (phase I and II),1ml
TR2014

The test reagents are intended for use in the serological detection and the determination of the serovar of Shigella strains isolated from test material of human or other origin using the slide agglutination test.

Principle of the test: If the Shigella strain possesses an antigen covered by the test reagent, this antigen becomes bound when mixed with the specific antibody. The antigen-antibody reaction results in clearly visible agglutination of the strain.

Control Antigen Salmonella Paratyphi  A-OH
TS1501

The control antigen is used to check the agglutinability of the sifin Anti-Salmonella O:2, Anti-Salmonella H:a test reagents and for quality control when carrying out the slide agglutination test. Paratyphi A-OH

Control Antigen Salmonella Paratyphi  B-OH
TS1502

The control antigen is used to check the agglutinability of the sifin Anti-Salmonella O:4, Anti-Salmonella O:5 Anti-Salmonella H:b, Anti-Salmonella H:1, Anti-Salmonella H:2 test reagents and for quality control when carrying out the lide agglutination test. Paratyphi B-OH

Control Antigen Salmonella Paratyphi  C-OH
TS1503

The control antigen is used to check the agglutinability of the sifin Anti-Salmonella O:7, Anti-Salmonella H:c, Anti-Salmonella H:1, Anti-Salmonella H:5 test reagents and for quality control when carrying out the slide agglutination test. Paratyphi C-OH

Control Antigen Salmonella Typhi-OH
TS1504

The control antigen is used to check the agglutinability of the sifin Anti-Salmonella O:9, Anti-Salmonella H:d test reagents and for quality control when carrying out the slide agglutination test. Typhi-OH

Control Antigen Salmonella Typhimurium-OH
TS1505

The control antigen is used to check the agglutinability of the sifin Anti-Salmonella O:4, Anti-Salmonella O:5, Anti-Salmonella H:i, Anti-Salmonella H:1, Anti-Salmonella H:2 test reagents and for quality control when carrying out the slide agglutination test. Typhimurium-OH

Control Antigen Salmonella Enteritidis-OH
TS1506

The control antigen is used to check the agglutinability of the sifin Anti-Salmonella O:9, Anti-Salmonella H:g, Anti-Salmonella H:m, Anti-Salmonella H:g,m test reagents and for quality control when carrying out the slide agglutination test. Enteritidis-OH

Control Antigen Salmonella Vi
TS1507

The control antigen is used to check the agglutinability of the sifin Anti-Salmonella Vi test reagent and for quality control when carrying out the slide agglutination test.

Control Antigen Shigella flexneri
TS1510
The control antigen is used to verify the agglutinability of the sifin test reagents Anti‑Shigella I and Anti‑Shigella flexneri, as well as for quality assurance of the test procedure using slide agglutination.
Control Antigen Shigella dysenteriae
TS1511
The control antigen is used to verify the agglutinability of the sifin test reagents Anti‑Shigella II, Anti‑Shigella dysenteriae type 1, and Anti‑Shigella dysenteriae type 2, and for quality assurance of the test procedure using slide agglutination.
Control Antigen Shigella boydii
TS1512
The control antigen is used to verify the agglutinability of the sifin test reagent Anti‑Shigella III and for quality assurance of the test procedure using slide agglutination.
Control Antigen Shigella sonnei
TS1513
The control antigen is used to verify the agglutinability of the sifin test reagents Anti‑Shigella I, Anti‑Shigella sonnei S form, Anti‑Shigella sonnei F form, and Anti‑Shigella sonnei S and F forms, as well as for quality assurance of the test procedure using slide agglutination.
Page 1 of 2

The product has been added to your shopping cart Show shopping cartCheckout