Your browser is not supported. For the best experience, a newer version or another browser is recommended.
atrium.jpg

VAI SMA Atrium

SMA Atrium is a unique microbiological air sampler that can be completely sterilized via steam, heat or ETO. Constructed of either anodized aluminum, 304 stainless steel or 316L stainless steel, the Atrium is very durable and needs little maintenance. The Atrium is sized at 4-1/2" in diameter by 1-1/2 inches in height. This compact size of the unit provides the opportunity to locate the sampling device near filling processes where space is limited. The small size of the unit coupled with its simplistic operation has enabled many operations to report accurately the air quality near fill areas and reduce false positives from operators.
Number of articles 33
Sort
Item no.
Display per page
316 Stainless Steel SMA
SMA-316-18-1/2
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

316 Stainless Steel SMA
SMA-316-18-1/2-OB
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

316 Stainless Steel SMA
SMA-316-18-1/4
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

316 Stainless Steel SMA
SMA-316-18-1/4-OB
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

316 Stainless Steel SMA
SMA-316-25-1/2
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

316 Stainless Steel SMA
SMA-316-25-1/2-OB
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

316 Stainless Steel SMA
SMA-316-25-1/4
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

316 Stainless Steel SMA
SMA-316-25-1/4-OB
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

316 Stainless Steel SMA
SMA-316-32-1/2
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

316 Stainless Steel SMA
SMA-316-32-1/2-OB
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

316 Stainless Steel SMA
SMA-316-32-1/4
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

316 Stainless Steel SMA
SMA-316-32-1/4-OB
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

316 Stainless Steel SMA Bottom
SMA-316-B
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

316 SS SMA Bottom for SMA-WALLATR
SMA-316-B-SC
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

316 Stainless Steel SMA Top
SMA-316-T-18-1/2
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

316 Stainless Steel SMA Top
SMA-316-T-18-1/4
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

316 Stainless Steel SMA Top
SMA-316-T-25-1/2
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

316 Stainless Steel SMA Top
SMA-316-T-25-1/4
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

316 Stainless Steel SMA Top
SMA-316-T-32-1/2
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

316 Stainless Steel SMA Top
SMA-316-T-32-1/4
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

Anodized Aluminum SMA
SMA-AA-18-1/2
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

Anodized Aluminum SMA
SMA-AA-18-1/4
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

Anodized Aluminum SMA
SMA-AA-25-1/2
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

Anodized Aluminum SMA
SMA-AA-25-1/4
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

Anodized Aluminum SMA
SMA-AA-32-1/2
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

Anodized Aluminum SMA
SMA-AA-32-1/4
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

Anodized Aluminum SMA Bottom
SMA-AA-B
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

Anodized Aluminum SMA Top
SMA-AA-T-18-1/2
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

Anodized Aluminum SMA Top
SMA-AA-T-18-1/4
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

Anodized Aluminum SMA Top
SMA-AA-T-25-1/2
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

Anodized Aluminum SMA Top
SMA-AA-T-25-1/4
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

Anodized Aluminum SMA Top
SMA-AA-T-32-1/2
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

Anodized Aluminum SMA Top
SMA-AA-T-32-1/4
  • Can be completely sterilized by steam, heat or ETO
  • Durable and low maintenance
  • 4 ½" in diameter by 1 ½" in height
  • Compact size allows the sampling device to be located near filling processes where space is limited
  • Reports accurately the air quality near fill areas and reduce false positives from operators
  • Operates at an air flow of 1 cubic foot per minute (1CFM)
  • Designed to provide a tortuous path that air must travel, which assures a 95% capture efficiency of 0.5 micron particles and larger
  • 12 top orifices available in ½", ¼" and 3 / 32 " provide the ability to sample for varying time periods
    • Top orifice size is dependent upon the desired exposure time versus desiccation of the nutrient media
    • 3/32" top orifice allows a maximum 60 minute exposure time
    • ¼" and ½" top orifices allow up to 3 hours of exposure time (dependent upon conditions)
  • Utilizes a 100 mm plate filled to either 25mL or 32mL of nutrient media (common fill levels from most suppliers)
    • The 25mL fill provides the ability to sample up to 90 minutes on one agar plate
    • The 32mL fill provides the ability to sample up to 3 hours on one agar plate (dependent upon conditions)
  • Requires only a vacuum source to operate
    • Sources can be either central vacuum systems or one of the VAI 1 thru 10 location control centers

Please contact Miclev for more information.

The product has been added to your shopping cart Show shopping cartCheckout