Hydrogen Peroxide Chemical Indicators

Crosstex offers a comprehensive product line of Chemical Indicators (CIs) used to monitor Hydrogen Peroxide (VH2O2/Plasma) sterilization processes. Our CIs are designed to meet ISO 11140 standards. Crosstex Chemical Indicators for VH2O2 Sterilization are:

  • Used to monitor VH2O2 sterilization processes
  • Available as Class/Type 1 and Class/Type 4 indicators
  • Designed to fit all your needs for sterilization indicators. Custom designed CIs are also available
  • Easy to use and minimal training is required
  • Manufactured with Crosstex’ Eco Friendly Sterilization Indicator Inks
Number of articles 5
Sort
Item no.
Indicator cir h2o2 y to b 5000 text
CPI-P03

Crosstex Vaporized Hydrogen Peroxide (VH2O2) Chemical Process Indicators (CPIs) meet performance specifications as outlined in ISO 11140-1

Sterilization of health care products – Chemical indicators – Part 1: General requirements, for Type 1 Process Indicators.

CPIs provide a fast and reliable visual check on items that were exposed to VH2O2.

Consistent color transition

No light sensitivity issues P

ermanent pressure-sensitive adhesive

Room temperature storage (15°C to 30°C)

Each shipment is accompanied by a Certificate of Analysis to ensure product quality and consistency

Process Plasma / VH202
Indications for Use The indicators are intended to monitor Plasma / VH2O2 sterilization processes utilizing = 2.3 mg/L of VH2O2. The indicators may not be suitable for monitoring disinfection processes. This product is labeled For Industrial Use Only.
Chemical Indicator CPI-P03: Initial Color: Yellow Signal Color: Blue Chemical Indicator Inks contain no lead or other toxic heavy metals. GPL-2000R: Initial Color: Light Red/Pink Signal Color: Purple
Compliance ISO 11140-1:2014 Sterilization of health care products – Chemical indicators- Part 1: General requirements
Shelf Life 2 years from the date of manufacture The date of manufacture is based on the day the indicating ink is applied to the substrate. The remaining shelf life upon receipt will be shorter than 2 years.
Storage Conditions 15°C to 30°C, 20-70% relative humidity
Description Circle Indicator Label 12.7 mm with imprinted text “BLUE IS H2O2 EXPOSED”
Indicators per Roll 5,000
Unexposed  
Exposed  
Circle Indicator Label – 9 mm
GPL-2000R

Crosstex Vaporized Hydrogen Peroxide (VH2O2) Chemical Process Indicators (CPIs) meet performance specifications as outlined in ISO 11140-1 Sterilization of health care products – Chemical indicators – Part 1: General requirements, for Type 1 Process Indicators.

CPIs provide a fast and reliable visual check on items that were exposed to VH2O2. Consistent color transition

No light sensitivity issues

Permanent pressure-sensitive adhesive

Room temperature storage (15°C to 30°C)

Each shipment is accompanied by a Certificate of Analysis to ensure product quality and consistency

Process Plasma / VH202
Indications for Use The indicators are intended to monitor Plasma / VH2O2 sterilization processes utilizing = 2.3 mg/L of VH2O2. The indicators may not be suitable for monitoring disinfection processes. This product is labeled For Industrial Use Only.
Chemical Indicator CPI-P03: Initial Color: Yellow Signal Color: Blue Chemical Indicator Inks contain no lead or other toxic heavy metals. GPL-2000R: Initial Color: Light Red/Pink Signal Color: Purple
Compliance ISO 11140-1:2014 Sterilization of health care products – Chemical indicators- Part 1: General requirements
Shelf Life 2 years from the date of manufacture The date of manufacture is based on the day the indicating ink is applied to the substrate. The remaining shelf life upon receipt will be shorter than 2 years.
Storage Conditions 15°C to 30°C, 20-70% relative humidity
Description Circle Indicator Label – 9 mm
Indicators per Roll 2,000
Unexposed  
Exposed  
VH2O2 Chemical Indicator Strip – Type 4
GPS-250R

Crosstex VH2O2 Chemical Indicator Strips are certified to meet chemical indicator specifications for pack monitoring when used in VH2O2 sterilization processes.

Crosstex evaluates the performance of every lot in state of the art equipment to ensure consistent and reliable performance.

Provide a distinct color change from red to blue upon exposure to VH2O2 processes

Demonstrate exceptional performance in the most widely used VH2O2 sterilizers Manufactured with synthetic material

ISO 11140-1 Type 4 Compliant

Process Plasma / VH2O2
Indications for Use The indicators are intended to monitor all cycles within the STERRAD® 100S, 200, NX, 100NX, and STERIS® V-PRO® vaporized hydrogen peroxide sterilizers. The VH2O2 Indicators are intended to be used with sterilization wraps, containers, cassettes, rails or pouches to distinguish between processed and unprocessed units for both Healthcare and Industrial applications. Class 4/Type 4 Multi-critical Process Variable Indicator Stated Value: – 2.3 mg/L ± 0.4 mg/L of VH2O2 at 50°C for 6 minutes
Indicator Strip Dimensions 101 mm x 16 mm (4” x 0.625”)
Packaging 250 Strips/Pack
Chemical Indicator Color transition from red to blue
Compliance ISO 11140-1:2014 Sterilization of health care products – Chemical indicators- Part 1: General requirements
Shelf Life 24 months from the date of manufacture
Storage Conditions 15°C to 30°C, 20% to 70% relative humidity
Description VH2O2 Chemical Indicator Strip – Type 4
Quantity 250/Pack
VH2O2 Tape (red to blue option)
HT-048

Crosstex VH2O2 Tape (red to blue option) is to be used as an external chemical indicator for packages to be sterilized in VH2O2 sterilization processes.

This is a process indicator that indicates the package has been exposed to VH2O2 during the sterilization process.

Each roll comes in its own dispenser box; just tear off appropriate length, remove liner and secure to wrap

Tape will change color from red to blue when exposed to 2.3 mg/L ± 0.4 mg/L of VH2O2 at 50°C for 6 minutes exposure time or longer.

15 month shelf life

ISO 11140-1 Type 1 Compliant

 

Process Plasma / VH2O2
Indications for Use The indicators are intended to monitor VH2O2 sterilization processes utilizing = 2.3 mg/L of VH2O2. The indicator tape may not be suitable for monitoring disinfection processes. Class 1/Type 1 Process Indicator Requirements: – 2.3 mg/L at 50°C for 6 minutes
Tape Dimensions 19 mm x 55 m (0.75” x 60 yards)
Packaging 24 Rolls/Case
Compliance ISO 11140-1:2014 Sterilization of health care products – Chemical indicators- Part 1: General requirements
Shelf Life 15 months from the date of manufacture The date of manufacture is based on the day the indicating ink is applied to the substrate. The remaining shelf life upon receipt will be shorter than 15 months
Storage Conditions 15°C to 30°C, 20-70% relative humidity
Width 19 mm (3/4?)
Length/Roll 55 m (60 yds)
Quantity 24 Rolls/Case
VH2O2 Tape (red to yellow option)
TAP-H48

Crosstex VH2O2 Tape (red to yellow option) is designed to aid in distinguishing processed from unprocessed loads.

The tape consists of a strong custom-made white polyester substrate with a pressure sensitive adhesive which adheres to Tyvek®, plastic, woven, treated woven and non-woven wraps.

The adhesive allows for secure seals yet is easy to remove.

Latex & Lead free Tape will change color from red to yellow when exposed to 2.3 mg/L ± 0.4 mg/L of VH2O2 at 50°C for 6 minutes exposure time or longer.

Can be written upon.

Long shelf life of 36 months.

Each shipment includes a Certificate of Analysis for assurance of product quality and performance ISO 11140-1 Type 1 Compliant

Tyvek® is a registered trademark of E.I. du Pont de Nemours and Company.

Process Plasma / VH2O2
Indications for Use

The indicators are intended to monitor VH2O2 sterilization processes utilizing = 2.3 mg/L of VH2O2.

The indicator tape may not be suitable for monitoring disinfection processes.

Class 1/Type 1 Process Indicator Requirements: – 2.3 mg/L at 50°C for 6 minutes This product is labeled for Industrial Use Only.

Tape Dimensions 19 mm x 55 m (0.75” x 60 yards)
Roll Outer Diameter 114 mm (4.5”)
Packaging 48 Rolls/Case
Compliance ISO 11140-1:2014 Sterilization of health care products – Chemical indicators- Part 1: General requirements
Shelf Life

3 years from the date of manufacture

The date of manufacture is based on the day the indicating ink is applied to the substrate. The remaining shelf life upon receipt will be shorter than 3 years

Storage Conditions 15°C to 30°C, 20-70% relative humidity
Width 19 mm (0.75”)
Length/Roll 55 m (60 yds)
Quantity 48 Rolls/Case