Gamma & E-beam Chemical Indicators

Crosstex is an industry leader manufacturing Chemical Indicators (CIs) used to monitor Gamma & E-Beam sterilization processes.  Our CIs are designed to meet ISO 11140 standards. Crosstex Chemical Indicators for Gamma & E-Beam sterilization are:

  • Used to monitor Gamma & E-Beam sterilization processes
  • Available as Class/Type 1 indicators in many different designs
  • Designed to fit all your needs for sterilization indicators. Custom-designed CIs are also available
  • Easy to use and minimal training is required
  • Manufactured with Crosstex’ Eco Friendly Sterilization Indicator Inks
Number of articles 5
Sort
Item no.
Indicator cir >10kgy y to r 5000
CPI-R01

Crosstex Gamma and E-Beam (Radiation) Chemical Process Indicators (CPIs) are manufactured with Crosstex’ Eco Friendly Indicating Inks (contains no latex, lead or other toxic heavy metals) and provide a fast and consistent visual check on items that were sterilized by Gamma or E-Beam Radiation. Consistent and irreversible color transition from Yellow to Red No light sensitivity issues Permanent pressure-sensitive adhesive

Process Radiation (Gamma and E-beam)
Indications for UseThe CPIs may be utilized to monitor Gamma and E-Beam sterilization processes. This product is labeled For Industrial Use Only.
Chemical IndicatorInitial Color : Yellow Signal Color : RedCPI-F01 (only) Initial Color : Green Signal Color : DarkChemical Indicator Inks contain no lead or other toxic heavy metals.
ComplianceISO 11140-1:2014 Sterilization of health care products – Chemical Indicators- Part 1: General Requirements
Shelf-Life24 months from the date of manufacture The date of manufacture is based on the day the indicating ink is applied to the substrate. The remaining shelf-life upon receipt will be shorter than 24 months.
Storage Conditions15°C to 30°C, 20-70% relative humidity
DescriptionPlain 12.7 mm
Dose Level=10kGy
Indicators Per Roll5,000
Unexposed
Exposed
Indicator Labels for hand-held labeling systems 25 mm x 12 mm
CPI-R02

Crosstex Gamma and E-Beam (Radiation) Chemical Process Indicators (CPIs) are manufactured with Crosstex’ Eco Friendly Indicating Inks (contains no latex, lead or other toxic heavy metals) and provide a fast and consistent visual check on items that were sterilized by Gamma or E-Beam Radiation. Consistent and irreversible color transition from Yellow to Red No light sensitivity issues Permanent pressure-sensitive adhesive

Process Radiation (Gamma and E-beam)
Indications for UseThe CPIs may be utilized to monitor Gamma and E-Beam sterilization processes. This product is labeled For Industrial Use Only.
Chemical IndicatorInitial Color : Yellow Signal Color : RedCPI-F01 (only) Initial Color : Green Signal Color : DarkChemical Indicator Inks contain no lead or other toxic heavy metals.
ComplianceISO 11140-1:2014 Sterilization of health care products – Chemical Indicators- Part 1: General Requirements
Shelf-Life24 months from the date of manufacture The date of manufacture is based on the day the indicating ink is applied to the substrate. The remaining shelf-life upon receipt will be shorter than 24 months.
Storage Conditions15°C to 30°C, 20-70% relative humidity
DescriptionIndicator Labels for hand-held labeling systems 25 mm x 12 mm
Dose Level=10kGy
Indicators Per Roll1,000
Unexposed
Exposed
Indicator cir >10kgy y to r 5000 text
CPI-R03

Crosstex Gamma and E-Beam (Radiation) Chemical Process Indicators (CPIs) are manufactured with Crosstex’ Eco Friendly Indicating Inks (contains no latex, lead or other toxic heavy metals) and provide a fast and consistent visual check on items that were sterilized by Gamma or E-Beam Radiation. Consistent and irreversible color transition from Yellow to Red No light sensitivity issues Permanent pressure-sensitive adhesive

Process Radiation (Gamma and E-beam)
Indications for UseThe CPIs may be utilized to monitor Gamma and E-Beam sterilization processes. This product is labeled For Industrial Use Only.
Chemical IndicatorInitial Color : Yellow Signal Color : RedCPI-F01 (only) Initial Color : Green Signal Color : DarkChemical Indicator Inks contain no lead or other toxic heavy metals.
ComplianceISO 11140-1:2014 Sterilization of health care products – Chemical Indicators- Part 1: General Requirements
Shelf-Life24 months from the date of manufacture The date of manufacture is based on the day the indicating ink is applied to the substrate. The remaining shelf-life upon receipt will be shorter than 24 months.
Storage Conditions15°C to 30°C, 20-70% relative humidity
DescriptionImprinted 12.7 mm Text reads: “Red is exposed”
Dose Level=10kGy
Indicators Per Roll5,000
Unexposed
Exposed
Indicator Labels for hand-held labeling systems 25 mm x 12 mm
CPI-R06

Crosstex Gamma and E-Beam (Radiation) Chemical Process Indicators (CPIs) are manufactured with Crosstex’ Eco Friendly Indicating Inks (contains no latex, lead or other toxic heavy metals) and provide a fast and consistent visual check on items that were sterilized by Gamma or E-Beam Radiation. Consistent and irreversible color transition from Yellow to Red No light sensitivity issues Permanent pressure-sensitive adhesive

Process Radiation (Gamma and E-beam)
Indications for UseThe CPIs may be utilized to monitor Gamma and E-Beam sterilization processes. This product is labeled For Industrial Use Only.
Chemical IndicatorInitial Color : Yellow Signal Color : RedCPI-F01 (only) Initial Color : Green Signal Color : DarkChemical Indicator Inks contain no lead or other toxic heavy metals.
ComplianceISO 11140-1:2014 Sterilization of health care products – Chemical Indicators- Part 1: General Requirements
Shelf-Life24 months from the date of manufacture The date of manufacture is based on the day the indicating ink is applied to the substrate. The remaining shelf-life upon receipt will be shorter than 24 months.
Storage Conditions15°C to 30°C, 20-70% relative humidity
DescriptionIndicator Labels for hand-held labeling systems 25 mm x 12 mm
Dose Level=1kGy
Indicators Per Roll1,000
Unexposed
Exposed
indicator cir >10kgy y to r 5000 text ?
SP-R58

Crosstex Gamma and E-Beam (Radiation) Chemical Process Indicators (CPIs) are manufactured with Crosstex’ Eco Friendly Indicating Inks (contains no latex, lead or other toxic heavy metals) and provide a fast and consistent visual check on items that were sterilized by Gamma or E-Beam Radiation. Consistent and irreversible color transition from Yellow to Red No light sensitivity issues Permanent pressure-sensitive adhesive

Process Radiation (Gamma and E-beam)
Indications for UseThe CPIs may be utilized to monitor Gamma and E-Beam sterilization processes. This product is labeled For Industrial Use Only.
Chemical IndicatorInitial Color : Yellow Signal Color : RedCPI-F01 (only) Initial Color : Green Signal Color : DarkChemical Indicator Inks contain no lead or other toxic heavy metals.
ComplianceISO 11140-1:2014 Sterilization of health care products – Chemical Indicators- Part 1: General Requirements
Shelf-Life24 months from the date of manufacture The date of manufacture is based on the day the indicating ink is applied to the substrate. The remaining shelf-life upon receipt will be shorter than 24 months.
Storage Conditions15°C to 30°C, 20-70% relative humidity
DescriptionImprinted 12.7 mm Text reads: “Red is ? exposed”
Dose Level=10kGy
Indicators Per Roll5,000
Unexposed
Exposed

The product has been added to your shopping cart Show shopping cartCheckout